Posted in

By

18 of 20Updated 2026-11-1722 min read中文版

Motion Alarm List

The alarms included in the FATEK M-PLC Alarm List are mainly divided into the following three types: Motion Flow Error Alarm, EtherCAT Communication Error Alarm and Axial Error Alarm. The aforesaid alarms will be stored in the respective Special Register.

17-1 Motion Flow Alarm

The Motion Flow error alarm comprises ID 1–ID 16 Motion control flow error codes and they are stored in R36932–R36947 special registers separately, as per the list below:

Motion Flow ID

Corresponding Register

ID 1

R36884

ID 2

R36885

ID 3

R36886

ID 4

R36887

ID 5

R36888

ID 6

R36889

ID 7

R36890

ID 8

R36891

ID 9

R36892

ID 10

R36893

ID 11

R36894

ID 12

R36895

ID 13

R36896

ID 14

R36897

ID 15

R36898

ID 16

R36899

ID 17

R36900

ID 18

R36901

ID 19

R36902

ID 20

R36903

M-PLC Motion Flow error alarm list:

Error Code

Symptom

Description

Solution

Stop Method

1

Motion Flow action axis error

Axis error detected when the Flow is running.

Remove the problem according to axis error instructions.

Stop instantly

2

Motion Flow action axis driver error

Driver error detected when the Flow is running.

Remove the problem according to Driver Manual.

Stop running the error axis

3

Motion Flow action axis driver alarm

Driver alarm detected when the Flow is running.

Remove the problem according to Driver Manual.

Stop the axis

4

Motion Flow action error

Computation error detected when the Flow is running.

Recheck the parameter set for the action.

Stop instantly

10

Position action positioning finish overtime

Inspection overtime after completing the action.

Extend the inspection time or add the allowable tolerance.

Stop the error axis

11

Position change target position error

Positioning curve type is incorrect, and only the linear interpolation can be used to change the target position.

Close or change the target position function.

Stop the error axis

20

Position action: Arc auxiliary circle error

Stop the error axis

21

Position action: Arc circular center mode error

Stop the error axis

22

Position action: Arc pass point mode error

Stop the error axis

23

Position action: Arc radius mode error

Stop the error axis

M-PLC Motion Flow error alarm list:R36882, R36883

R36882

R36883 display

Description

cause

Solution

1

Motion flow number (01~16) + 00 + error code (1)

Axis error occurred

Axis error occurred

Check the axis error information and troubleshoot the error.

2

Motion flow number (01~16) + 00 + error code (2)

Drive error occurred

Drive error occurred

Check the drive panel and troubleshoot the error.

3

Motion flow number (01~16) + 00 + error code (3)

Drive error occurred

Drive error occurred

Check the drive panel and troubleshoot the error.

4

Motion flow number (01~16) + branch number (01~20) + error code (4)

Ex:

When a motion block number 11 encounters an initialization error in the second branch, the code will be displayed as 11024.

Motion block initialization error.

Positioning point parameter error.

Identify the error branch , find the point number where the error flow block is running , use software or commands to read the recipe, and obtain and check the parameters of the error point.

17-2 EtherCAT Communication Error Alarm

The error code of EtherCAT communication error alarm is displayed by Special Register R36883. Provided below are the R36883 error alarm codes:

Motion controller status

R36880

R36881

Description

cause

Solution

STATUS_CODE_WARNING

2

Motion CPU Alarm

Motion CPU has an alarm, but does not stop.

Check the value of R36881.

STATUS_CODE_TRAPPING

4

Motion CPU Error

Motion CPU has an error, causing a shutdown.

Check the value of R36881.

STATUS_CODE_WARNING & STATUS_CODE_TRAPPING

6

Motion CPU Alarm and Error

Motion CPU has both an alarm and an error, causing a shutdown.

Check the value of R36881.

9998

PLC emergency stop.

PLC emergency stop.

After solving the PLC error, restart the system.

ERT_ECTM_SWINIT_MISMATCH

507

EtherCAT initializati failed.

Incorrect Slave Axis Brand.

1.Check the EtherCAT wiring.

2.Verify the Motion project configuration.

3.Record the values and report to the manufacturer.

ERT_ECTM_SWINIT_WRONG_SLVCNT_DETECT

508

EtherCAT initializati failed.

Incorrect Number of Slave Axes

1.Check the EtherCAT wiring.

2.Verify the Motion project configuration.

3.Record the values and report to the manufacturer.

others

Other errors.

Note the number of R36881 and report to the manufacturer.

17-3 Action Axis Alarm

The action axis error alarm is stored in Special Register R37004, and each action axis shall correspond to the respective register. Regarding this, “R37004” is used as the special register required for storing Axis-1 error alarm, Axis-2 error alarm special register is R37004+150 and Axis-3 is R37004+300, and so on. Each axis shall accommodate 150 error alarms. Provided below is the special register list for each axis:

Action axis error alarm

Corresponding Register

Axis 1

R37004

Axis 2

R37154

Axis 3

R37304

Axis 4

R37454

Axis 5

R37604

Axis 6

R37754

Axis 7

R37904

Axis 8

R38054

Axis 9

R38204

Axis 10

R38354

Axis 11

R38504

Axis 12

R38654

Axis 13

R38804

Axis 14

R38954

Axis 15

R39104

Axis 16

R39254

M-PLC Action Axis Error Alarm List:

Information 1

code

Information 2

Description

cause

Solution

AXIS_NOT_ENABLE

1

Current flow block number

Action axis is not enabled

Action axis is not enabled before running Motion Flow

Check if the enable relay of the motion axis is off or not triggered.

AXIS_NOT_READY

2

Current flow block number

Action axis is not ready

Encoder not ready before running Motion Flow.

Check if drive status is normal.

AXIS_POS_SW_LIMIT

3

Current flow block numberv

Action axis positive software limit limit

Action axis reaches positive software limit.

1. Check the axis table setting.

2. Check the target position coordinate.

AXIS_NEG_SW_LIMIT

4

Current flow block number

Action axis negative software limit

Action axis reaches negative software limit

1. Check the axis table setting.

2. Check the target position coordinate.

AXIS_POS_LS

5

Current flow block number

Action axis positive software limit switch

Positive limit switch is triggered.

1. Check the device wiring.

2. Check the switch pin configuration.

3. Check the target position coordinate.

AXIS_NEG_LS

6

Current flow block number

Action axis negative software limit switch

Negative limit switch is triggered.

1. Check the device wiring.

2. Check the switch pin configuration.

3. Check the target position coordinate.

AXIS_POS_LS_TRIG_NEG_MOV

7

Current flow block number

The positive limit switch is triggered when moving in negative direction.

The motion direction is opposite to the direction of the limit switches.

1. Check the device wiring.

2. Check the switch pin configuration.

AXIS_NEG_LS_TRIG_POS_MOV

8

Current flow block number

The negative limit switch is triggered when moving in positive direction.

The motion direction is opposite to the direction of the limit switches.

1. Check the device wiring.

2. Check the switch pin configuration.

AXIS_BASE_VEL_OVER_MAX_VEL

9

Current flow block number

The start speed of the axis is higher than the maximum speed value.

The start speed of the axis is higher than the maximum speed value.

Check the maximum speed and start speed set in the axis table.

AXIS_CMD_VEL_OVER_MAX_VEL

10

Current flow block number

The command speed of the axis is higher than the maximum speed value.

The command speed of the axis is higher than the maximum speed value.

1. Check the maximum speed of the target point.

2. Check the maximum speed set in the axis table.

AXIS_OCCUPIED

11

Current flow block number

Axis is in use.

The called axis is currently in control.

1. Ensure to wait for the completion of the previous action."

2. Check if the same command is called repeatedly.

AXIS_TORQ_PROTECT

12

Current flow block number

Torque protection is triggered.

The torque feedback exceeds the torque limit scope indicated in the Axis Table.

1. Check if there is any interference between mechanisms.

2. Set the maximum torque in the positive or negative direction to a appropriate value in the axis table settings.

AXIS_POS_ARC_AUXPAR

20

Current flow block number

Positioning: Auxiliary circle calculation error

The auxiliary circle radius setting in position mode is too large.

Set the auxiliary circle radius to an appropriate size.

AXIS_POS_ARC_CENTER

21

Current flow block number

Positioning: Arc circular center mode error

The center of the circular interpolation arc is set incorrectly.

Center of circle,start point and end point coordinates cannot lie on the same line.

AXIS_POS_ARC_BORDER

22

Current flow block number

Positioning: Arc Border Point mode error

The circular interpolation border point is set incorrectly.

Border point,start point and end point coordinates cannot lie on the same line.

AXIS_POS_ARC_RADIUS

23

Current flow block number

Positioning: Arc radius mode error

The circular interpolation radius is set incorrectly.

The diameter length cannot be less than the linear distance between the start and end points.

AXIS_POS_TIME_OUT

24

Current flow block number

Positioning check completed timeout

Positioning check timeout

1. Check if the drive’s positioning control response is too slow.

2. Increase the pos don tolerance in the axis table.

3. Increase the pos don check time in the axis table.

FLOW_POS_CHG_WRONG_TYPE

25

Current flow block number

Positioning control interruption not supported in the current mode.

Positioning control is using an incorrect interrupt mode.

Interrupt constant feed and interrupt constant angle cannot be used in multi-axis interpolation.

AXIS_HOMING_FAIL

29

Current flow block number

Homing failure

Doesn’t found the home signal during homing process.

1. Check the device wiring.

2. Check the switch pin configuration.

AXIS_POS_PTYE

30

Current flow block number

Point table parameter operation mode error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_POS_CTYPE

31

Current flow block number

Point table parameter acceleration profile error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_POS_PROFILE

32

Current flow block number

Point table parameter speed planning error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_POS_ACCPER

33

Current flow block number

Point table parameter S- curve acceleration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_POS_DECPER

34

Current flow block number

Point table parameter S- curve deceleration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_POS_CIRMODE

35

Current flow block number

Point table parameter arc mode error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_POS_CIRDIR

36

Current flow block number

Point table parameter arc direction error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_POS_CIRRAD

37

Current flow block number

Point table parameter arc radius error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_POS_NEXTPOINT

38

Current flow block number

Point table parameter continuous point number error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_POS_CONTIMODE

39

Current flow block number

Point table parameter continuous mode error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_OVER_REVERSE

50

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_ECAM_SWITCH

51

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_UNIT

52

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_FRACTION

53

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_INPUT_INIT

54

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_CAM_INIT

55

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_IN1_TYPE

56

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_IN1_EXTNUM

57

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_IN1_AXISNUM

58

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_IN1_REVERSE

59

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_IN1_TRANS_METHOD

60

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_IN1_TRANS_DEN

61

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_IN2_TYPE

62

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_IN2_EXTNUM

63

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_IN2_AXISNUM

64

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_IN2_REVERSE

65

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_IN2_TRANS_METHOD

66

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_IN2_TRANS_DEN

67

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_INA_TYPE

68

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_INA_EXTNUM

69

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_INA_AXISNUM

70

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_INA_REVERSE

71

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_INA_TRANS_METHOD

72

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_INA_TRANS_DEN

73

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_MAIN_CMP_MODE

74

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_AUX_CMP_MODE

75

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_GEAR_DEN

76

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_GEAR_MODE

77

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_MCLUTCH_ON_COND

78

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_MCLUTCH_ON_METHOD

79

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_MCLUTCH_ON_SLIDE_MODE

80

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_MCLUTCH_ON_SLIDE_CURVE

81

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_MCLUTCH_OFF_COND

82

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_MCLUTCH_OFF_METHOD

83

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_MCLUTCH_OFF_SLIDE_MODE

84

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_MCLUTCH_OFF_SLIDE_CURVE

85

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_ACLUTCH_ON_COND

86

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_ACLUTCH_ON_METHOD

87

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_ACLUTCH_ON_SLIDE_MODE

88

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_ACLUTCH_ON_SLIDE_CURVE

89

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_ACLUTCH_OFF_COND

90

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_ACLUTCH_OFF_METHOD

91

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_ACLUTCH_OFF_SLIDE_MODE

92

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_ACLUTCH_OFF_SLIDE_CURVE

93

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_TCLUTCH_STOP_METHOD

94

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_TCLUTCH_CON_METHOD

95

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_TCLUTCH_JOGSPEED

96

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_STEP_CMP_MODE

97

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_ECAM_ID

98

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_CONTACT_NUM

99

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.

2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_SYNC_PERIOD_ZERO

100

Current flow block number

Sync parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_DATA_ENCFALG

110

Current flow block number

Motion axis parameter table configuration error

Mapping illegal values.

1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_DATA_UNIT

111

Current flow block number

Motion axis parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_DATA_FRACTION

112

Current flow block number

Motion axis parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_DATA_VELUNIT

113

Current flow block number

Motion axis parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_DATA_STOPMETHOD

114

Current flow block number

Motion axis parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_DATA_QSTOPDEC

115

Current flow block number

Motion axis parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_DATA_HOMEMODE

116

Current flow block number

Motion axis parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_DATA_SIGSOURCE

117

Current flow block number

Motion axis parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_DATA_HOMEDIR

118

Current flow block number

Motion axis parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_DATA_HOMEBIT

119

Current flow block number

Motion axis parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_DATA_JOGPROFILE

120

Current flow block number

Motion axis parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_DATA_SOFTLIMIT

121

Current flow block number

Motion axis parameter table configuration error.

Mapping illegal values.

1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual.

AXIS_FLOW_ERROR

190

Current flow block number

Motion flow error

Motion flow occurs an error and sync control stop.

Troubleshoot the faulty axis or other factors causing the error.

AXIS_MAPPING_ERROR

193

Error mapping table number

Mapping parameter error

Parameter out of range in mapping table or function 181.

Confirm the correct mapping parameter number from the manual.

AXIS_UPDATE_ERROR

194

0

Ladder instruction update parameter error

Ladder instruction UPD updated an invalid value.

Identify the instruction reporting ERR and check for inputted values that might be inappropriate.

AXIS_DRIVE_ERROR

200

Current flow block number

Drive error.

After connecting the axis, a drive error. occurred.

1. After troubleshooting, restart the device.

2. After troubleshooting, reset axis to clear the error.

AXIS_DRIVE_DISCONNECT

201

EtherCAT connection lost.

EtherCAT disconnected after axis connection.

AXIS_DRIVE_ECERROR

202

System EtherCAT communication error.

EtherCAT disconnection occurred on other axes.

M-PLC Axis warning detail information:

Information 1

code

Information 2

Description

cause

Solution

AXIS_HOMING_SMALL_DEC

27

Current flow block number

Homing deceleration zone beyond the home position range.

During the deceleration process to creeping velocity while homing, the deceleration should be completed within the home sensing area.

1. Increase homing mode deceleration value.

2. Increase the range of the home sensing area.

AXIS_FLOW_END

189

Current flow number

Motion flow stops when axis control is active.

Motion flow is stopped or enters the end flow block when axis is in control.

1. Check if the logic is correct.

2. Reset axis to clear the error.

AXIS_FLOW_ESTOP

191

Current flow block number

Motion flow emergency stop

Motion aborted while in axis control.

1. Check if the logic is correct.

2. Reset axis to clear the error.

AXIS_FLOW_DECSTOP

192

Current flow block number

Motion flow deceleration stop

Motion aborted while in axis control.

1. Check if the logic is correct.

2. Reset axis to clear the error.

AXIS_COMMAND_MISMATCH

203

The actual position and current position are not the same during standby

System EtherCAT communication error.

If the issue persists, please check the EtherCAT wiring and restart the system.

Was this page helpful?

Tip: press ← → to switch chapters, Ctrl+K to search