Motion Alarm List
The alarms included in the FATEK M-PLC Alarm List are mainly divided into the following three types: Motion Flow Error Alarm, EtherCAT Communication Error Alarm and Axial Error Alarm. The aforesaid alarms will be stored in the respective Special Register.
17-1 Motion Flow Alarm
The Motion Flow error alarm comprises ID 1–ID 16 Motion control flow error codes and they are stored in R36932–R36947 special registers separately, as per the list below:
|
Motion Flow ID |
Corresponding Register |
|
ID 1 |
R36884 |
|
ID 2 |
R36885 |
|
ID 3 |
R36886 |
|
ID 4 |
R36887 |
|
ID 5 |
R36888 |
|
ID 6 |
R36889 |
|
ID 7 |
R36890 |
|
ID 8 |
R36891 |
|
ID 9 |
R36892 |
|
ID 10 |
R36893 |
|
ID 11 |
R36894 |
|
ID 12 |
R36895 |
|
ID 13 |
R36896 |
|
ID 14 |
R36897 |
|
ID 15 |
R36898 |
|
ID 16 |
R36899 |
|
ID 17 |
R36900 |
|
ID 18 |
R36901 |
|
ID 19 |
R36902 |
|
ID 20 |
R36903 |
M-PLC Motion Flow error alarm list:
|
Error Code |
Symptom |
Description |
Solution |
Stop Method |
|
1 |
Motion Flow action axis error |
Axis error detected when the Flow is running. |
Remove the problem according to axis error instructions. |
Stop instantly |
|
2 |
Motion Flow action axis driver error |
Driver error detected when the Flow is running. |
Remove the problem according to Driver Manual. |
Stop running the error axis |
|
3 |
Motion Flow action axis driver alarm |
Driver alarm detected when the Flow is running. |
Remove the problem according to Driver Manual. |
Stop the axis |
|
4 |
Motion Flow action error |
Computation error detected when the Flow is running. |
Recheck the parameter set for the action. |
Stop instantly |
|
10 |
Position action positioning finish overtime |
Inspection overtime after completing the action. |
Extend the inspection time or add the allowable tolerance. |
Stop the error axis |
|
11 |
Position change target position error |
Positioning curve type is incorrect, and only the linear interpolation can be used to change the target position. |
Close or change the target position function. |
Stop the error axis |
|
20 |
Position action: Arc auxiliary circle error |
Stop the error axis |
||
|
21 |
Position action: Arc circular center mode error |
Stop the error axis |
||
|
22 |
Position action: Arc pass point mode error |
Stop the error axis |
||
|
23 |
Position action: Arc radius mode error |
Stop the error axis |
M-PLC Motion Flow error alarm list:R36882, R36883
|
R36882 |
R36883 display |
Description |
cause |
Solution |
|
1 |
Motion flow number (01~16) + 00 + error code (1) |
Axis error occurred |
Axis error occurred |
Check the axis error information and troubleshoot the error. |
|
2 |
Motion flow number (01~16) + 00 + error code (2) |
Drive error occurred |
Drive error occurred |
Check the drive panel and troubleshoot the error. |
|
3 |
Motion flow number (01~16) + 00 + error code (3) |
Drive error occurred |
Drive error occurred |
Check the drive panel and troubleshoot the error. |
|
4 |
Motion flow number (01~16) + branch number (01~20) + error code (4) Ex: When a motion block number 11 encounters an initialization error in the second branch, the code will be displayed as 11024. |
Motion block initialization error. |
Positioning point parameter error. |
Identify the error branch , find the point number where the error flow block is running , use software or commands to read the recipe, and obtain and check the parameters of the error point. |
17-2 EtherCAT Communication Error Alarm
The error code of EtherCAT communication error alarm is displayed by Special Register R36883. Provided below are the R36883 error alarm codes:
|
Motion controller status |
R36880 |
R36881 |
Description |
cause |
Solution |
|
STATUS_CODE_WARNING |
2 |
Motion CPU Alarm |
Motion CPU has an alarm, but does not stop. |
Check the value of R36881. |
|
|
STATUS_CODE_TRAPPING |
4 |
Motion CPU Error |
Motion CPU has an error, causing a shutdown. |
Check the value of R36881. |
|
|
STATUS_CODE_WARNING & STATUS_CODE_TRAPPING |
6 |
Motion CPU Alarm and Error |
Motion CPU has both an alarm and an error, causing a shutdown. |
Check the value of R36881. |
|
|
9998 |
PLC emergency stop. |
PLC emergency stop. |
After solving the PLC error, restart the system. |
||
|
ERT_ECTM_SWINIT_MISMATCH |
507 |
EtherCAT initializati failed. |
Incorrect Slave Axis Brand. |
1.Check the EtherCAT wiring. 2.Verify the Motion project configuration. 3.Record the values and report to the manufacturer. |
|
|
ERT_ECTM_SWINIT_WRONG_SLVCNT_DETECT |
508 |
EtherCAT initializati failed. |
Incorrect Number of Slave Axes |
1.Check the EtherCAT wiring. 2.Verify the Motion project configuration. 3.Record the values and report to the manufacturer. |
|
|
others |
Other errors. |
Note the number of R36881 and report to the manufacturer. |
17-3 Action Axis Alarm
The action axis error alarm is stored in Special Register R37004, and each action axis shall correspond to the respective register. Regarding this, “R37004” is used as the special register required for storing Axis-1 error alarm, Axis-2 error alarm special register is R37004+150 and Axis-3 is R37004+300, and so on. Each axis shall accommodate 150 error alarms. Provided below is the special register list for each axis:
|
Action axis error alarm |
Corresponding Register |
|
Axis 1 |
R37004 |
|
Axis 2 |
R37154 |
|
Axis 3 |
R37304 |
|
Axis 4 |
R37454 |
|
Axis 5 |
R37604 |
|
Axis 6 |
R37754 |
|
Axis 7 |
R37904 |
|
Axis 8 |
R38054 |
|
Axis 9 |
R38204 |
|
Axis 10 |
R38354 |
|
Axis 11 |
R38504 |
|
Axis 12 |
R38654 |
|
Axis 13 |
R38804 |
|
Axis 14 |
R38954 |
|
Axis 15 |
R39104 |
|
Axis 16 |
R39254 |
M-PLC Action Axis Error Alarm List:
|
Information 1 |
code |
Information 2 |
Description |
cause |
Solution |
|---|---|---|---|---|---|
|
AXIS_NOT_ENABLE |
1 |
Current flow block number |
Action axis is not enabled |
Action axis is not enabled before running Motion Flow |
Check if the enable relay of the motion axis is off or not triggered. |
|
AXIS_NOT_READY |
2 |
Current flow block number |
Action axis is not ready |
Encoder not ready before running Motion Flow. |
Check if drive status is normal. |
|
AXIS_POS_SW_LIMIT |
3 |
Current flow block numberv |
Action axis positive software limit limit |
Action axis reaches positive software limit. |
1. Check the axis table setting. 2. Check the target position coordinate. |
|
AXIS_NEG_SW_LIMIT |
4 |
Current flow block number |
Action axis negative software limit |
Action axis reaches negative software limit |
1. Check the axis table setting. 2. Check the target position coordinate. |
|
AXIS_POS_LS |
5 |
Current flow block number |
Action axis positive software limit switch |
Positive limit switch is triggered. |
1. Check the device wiring. 2. Check the switch pin configuration. 3. Check the target position coordinate. |
|
AXIS_NEG_LS |
6 |
Current flow block number |
Action axis negative software limit switch |
Negative limit switch is triggered. |
1. Check the device wiring. 2. Check the switch pin configuration. 3. Check the target position coordinate. |
|
AXIS_POS_LS_TRIG_NEG_MOV |
7 |
Current flow block number |
The positive limit switch is triggered when moving in negative direction. |
The motion direction is opposite to the direction of the limit switches. |
1. Check the device wiring. 2. Check the switch pin configuration. |
|
AXIS_NEG_LS_TRIG_POS_MOV |
8 |
Current flow block number |
The negative limit switch is triggered when moving in positive direction. |
The motion direction is opposite to the direction of the limit switches. |
1. Check the device wiring. 2. Check the switch pin configuration. |
|
AXIS_BASE_VEL_OVER_MAX_VEL |
9 |
Current flow block number |
The start speed of the axis is higher than the maximum speed value. |
The start speed of the axis is higher than the maximum speed value. |
Check the maximum speed and start speed set in the axis table. |
|
AXIS_CMD_VEL_OVER_MAX_VEL |
10 |
Current flow block number |
The command speed of the axis is higher than the maximum speed value. |
The command speed of the axis is higher than the maximum speed value. |
1. Check the maximum speed of the target point. 2. Check the maximum speed set in the axis table. |
|
AXIS_OCCUPIED |
11 |
Current flow block number |
Axis is in use. |
The called axis is currently in control. |
1. Ensure to wait for the completion of the previous action." 2. Check if the same command is called repeatedly. |
|
AXIS_TORQ_PROTECT |
12 |
Current flow block number |
Torque protection is triggered. |
The torque feedback exceeds the torque limit scope indicated in the Axis Table. |
1. Check if there is any interference between mechanisms. 2. Set the maximum torque in the positive or negative direction to a appropriate value in the axis table settings. |
|
AXIS_POS_ARC_AUXPAR |
20 |
Current flow block number |
Positioning: Auxiliary circle calculation error |
The auxiliary circle radius setting in position mode is too large. |
Set the auxiliary circle radius to an appropriate size. |
|
AXIS_POS_ARC_CENTER |
21 |
Current flow block number |
Positioning: Arc circular center mode error |
The center of the circular interpolation arc is set incorrectly. |
Center of circle,start point and end point coordinates cannot lie on the same line. |
|
AXIS_POS_ARC_BORDER |
22 |
Current flow block number |
Positioning: Arc Border Point mode error |
The circular interpolation border point is set incorrectly. |
Border point,start point and end point coordinates cannot lie on the same line. |
|
AXIS_POS_ARC_RADIUS |
23 |
Current flow block number |
Positioning: Arc radius mode error |
The circular interpolation radius is set incorrectly. |
The diameter length cannot be less than the linear distance between the start and end points. |
|
AXIS_POS_TIME_OUT |
24 |
Current flow block number |
Positioning check completed timeout |
Positioning check timeout |
1. Check if the drive’s positioning control response is too slow. 2. Increase the pos don tolerance in the axis table. 3. Increase the pos don check time in the axis table. |
|
FLOW_POS_CHG_WRONG_TYPE |
25 |
Current flow block number |
Positioning control interruption not supported in the current mode. |
Positioning control is using an incorrect interrupt mode. |
Interrupt constant feed and interrupt constant angle cannot be used in multi-axis interpolation. |
|
AXIS_HOMING_FAIL |
29 |
Current flow block number |
Homing failure |
Doesn’t found the home signal during homing process. |
1. Check the device wiring. 2. Check the switch pin configuration. |
|
AXIS_POS_PTYE |
30 |
Current flow block number |
Point table parameter operation mode error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_POS_CTYPE |
31 |
Current flow block number |
Point table parameter acceleration profile error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_POS_PROFILE |
32 |
Current flow block number |
Point table parameter speed planning error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_POS_ACCPER |
33 |
Current flow block number |
Point table parameter S- curve acceleration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_POS_DECPER |
34 |
Current flow block number |
Point table parameter S- curve deceleration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_POS_CIRMODE |
35 |
Current flow block number |
Point table parameter arc mode error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_POS_CIRDIR |
36 |
Current flow block number |
Point table parameter arc direction error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_POS_CIRRAD |
37 |
Current flow block number |
Point table parameter arc radius error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_POS_NEXTPOINT |
38 |
Current flow block number |
Point table parameter continuous point number error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_POS_CONTIMODE |
39 |
Current flow block number |
Point table parameter continuous mode error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_OVER_REVERSE |
50 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_ECAM_SWITCH |
51 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_UNIT |
52 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_FRACTION |
53 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_INPUT_INIT |
54 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_CAM_INIT |
55 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_IN1_TYPE |
56 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_IN1_EXTNUM |
57 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_IN1_AXISNUM |
58 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_IN1_REVERSE |
59 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_IN1_TRANS_METHOD |
60 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_IN1_TRANS_DEN |
61 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_IN2_TYPE |
62 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_IN2_EXTNUM |
63 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_IN2_AXISNUM |
64 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_IN2_REVERSE |
65 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_IN2_TRANS_METHOD |
66 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_IN2_TRANS_DEN |
67 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_INA_TYPE |
68 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_INA_EXTNUM |
69 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_INA_AXISNUM |
70 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_INA_REVERSE |
71 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_INA_TRANS_METHOD |
72 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_INA_TRANS_DEN |
73 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_MAIN_CMP_MODE |
74 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_AUX_CMP_MODE |
75 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_GEAR_DEN |
76 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_GEAR_MODE |
77 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_MCLUTCH_ON_COND |
78 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_MCLUTCH_ON_METHOD |
79 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_MCLUTCH_ON_SLIDE_MODE |
80 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_MCLUTCH_ON_SLIDE_CURVE |
81 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_MCLUTCH_OFF_COND |
82 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_MCLUTCH_OFF_METHOD |
83 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_MCLUTCH_OFF_SLIDE_MODE |
84 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_MCLUTCH_OFF_SLIDE_CURVE |
85 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_ACLUTCH_ON_COND |
86 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_ACLUTCH_ON_METHOD |
87 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_ACLUTCH_ON_SLIDE_MODE |
88 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_ACLUTCH_ON_SLIDE_CURVE |
89 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_ACLUTCH_OFF_COND |
90 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_ACLUTCH_OFF_METHOD |
91 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_ACLUTCH_OFF_SLIDE_MODE |
92 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_ACLUTCH_OFF_SLIDE_CURVE |
93 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_TCLUTCH_STOP_METHOD |
94 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_TCLUTCH_CON_METHOD |
95 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_TCLUTCH_JOGSPEED |
96 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_STEP_CMP_MODE |
97 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_ECAM_ID |
98 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_CONTACT_NUM |
99 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_SYNC_PERIOD_ZERO |
100 |
Current flow block number |
Sync parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_DATA_ENCFALG |
110 |
Current flow block number |
Motion axis parameter table configuration error |
Mapping illegal values. |
1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_DATA_UNIT |
111 |
Current flow block number |
Motion axis parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_DATA_FRACTION |
112 |
Current flow block number |
Motion axis parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_DATA_VELUNIT |
113 |
Current flow block number |
Motion axis parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_DATA_STOPMETHOD |
114 |
Current flow block number |
Motion axis parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_DATA_QSTOPDEC |
115 |
Current flow block number |
Motion axis parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_DATA_HOMEMODE |
116 |
Current flow block number |
Motion axis parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_DATA_SIGSOURCE |
117 |
Current flow block number |
Motion axis parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_DATA_HOMEDIR |
118 |
Current flow block number |
Motion axis parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_DATA_HOMEBIT |
119 |
Current flow block number |
Motion axis parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_DATA_JOGPROFILE |
120 |
Current flow block number |
Motion axis parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software. 2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_DATA_SOFTLIMIT |
121 |
Current flow block number |
Motion axis parameter table configuration error. |
Mapping illegal values. |
1. Confirm the correct range from the PLC software.2. Confirm the correct data length and sign of the mapping parameters from the manual. |
|
AXIS_FLOW_ERROR |
190 |
Current flow block number |
Motion flow error |
Motion flow occurs an error and sync control stop. |
Troubleshoot the faulty axis or other factors causing the error. |
|
AXIS_MAPPING_ERROR |
193 |
Error mapping table number |
Mapping parameter error |
Parameter out of range in mapping table or function 181. |
Confirm the correct mapping parameter number from the manual. |
|
AXIS_UPDATE_ERROR |
194 |
0 |
Ladder instruction update parameter error |
Ladder instruction UPD updated an invalid value. |
Identify the instruction reporting ERR and check for inputted values that might be inappropriate. |
|
AXIS_DRIVE_ERROR |
200 |
Current flow block number |
Drive error. |
After connecting the axis, a drive error. occurred. |
1. After troubleshooting, restart the device. 2. After troubleshooting, reset axis to clear the error. |
|
AXIS_DRIVE_DISCONNECT |
201 |
EtherCAT connection lost. |
EtherCAT disconnected after axis connection. |
||
|
AXIS_DRIVE_ECERROR |
202 |
System EtherCAT communication error. |
EtherCAT disconnection occurred on other axes. |
M-PLC Axis warning detail information:
|
Information 1 |
code |
Information 2 |
Description |
cause |
Solution |
|
AXIS_HOMING_SMALL_DEC |
27 |
Current flow block number |
Homing deceleration zone beyond the home position range. |
During the deceleration process to creeping velocity while homing, the deceleration should be completed within the home sensing area. |
1. Increase homing mode deceleration value. 2. Increase the range of the home sensing area. |
|
AXIS_FLOW_END |
189 |
Current flow number |
Motion flow stops when axis control is active. |
Motion flow is stopped or enters the end flow block when axis is in control. |
1. Check if the logic is correct. 2. Reset axis to clear the error. |
|
AXIS_FLOW_ESTOP |
191 |
Current flow block number |
Motion flow emergency stop |
Motion aborted while in axis control. |
1. Check if the logic is correct. 2. Reset axis to clear the error. |
|
AXIS_FLOW_DECSTOP |
192 |
Current flow block number |
Motion flow deceleration stop |
Motion aborted while in axis control. |
1. Check if the logic is correct. 2. Reset axis to clear the error. |
|
AXIS_COMMAND_MISMATCH |
203 |
The actual position and current position are not the same during standby |
System EtherCAT communication error. |
If the issue persists, please check the EtherCAT wiring and restart the system. |
Tip: press ← → to switch chapters, Ctrl+K to search