Posted in

By

2 of 24Updated 2026-11-174 min read中文版

2.1

Single-Unit System of FBS-PLC

Intelligent

Peripherals

BASE

Digital I/O Expansion Unit/Module

TC

HMI

FBS-24XY

Load Cell

FBS-40XY

DI

Bar-code Reader

Ethernet (Port4)

FBS-1HLC

Cell Phone

FBS-60XY

FBS-8XY

FBS-8X

Digital Input(DI)

FBS-8Y

FBS-16XY

SCADA

Main

FBS-16Y

FBS-CMGSM

FBS-20X

FBS-24X

FBS-CM25E

FBS-24YT

Port4

FBS-CM55E

FBS-24YJ

DO

FBS-CM22

Analog I/O Expansion Module

Port3

FBS-CM55

Unit

FBs-30GM

FBS-CM25

FBS-10MA/MC

FBS-6AD

FBS-2DA

AI

Port4

FBS-14MA/MC

FBS-4DA

FBS-20MA/MC

FBS-4A2D

AO

USB or

Port3

FBS-24MA/MC

RS232

Port0 Port0

FBS-32MA/MC

FBS-2A4TC

FP-08

Data

Port2

FBS-40MA/MC

FBS-2A4RTD

Port1

FBS-60MA/MC

FBS-2TC

Access

FBS-20MN

FBS-6TC

Port2

FBS-BDAP

FBS-32MN

FBS-6RTD

RTD

FBS-44MN

FBS-16TC

FBS-BPEP

FBS-16RTD

FBs-PEP

Port1

FBS-CB2

FBs-6NTC

FBS-CB22

Temperature Input Module

FBS-CB5

FBs-DAP(R)

Ethernet (Port1,2)

FBS-CB55

Server

FBS-7SG1

9

FBS-CB25

FBS-7SG2

FBS-CBE

FBS-32DGI

6

7

8

FBs-CBCAN

Numeric I/O Expansion

FBS-B4AD

Digital Output (DO)

Load cell

FBs-VOM

FBS-B2DA

FBS-B2A1D

Voice Output Module

FBs-1LC

RFID Card

AI

AO

Load Cell Module

The Single-Unit system means a system built only by a single FBs-PLC and its expansion unit/modules and communication boards/modules. Such system have a limited capability (refer), beyond that capability can incorporate CPU communication via LINK function for expansions (please refer to the next paragraph). The figure below shows the block diagram of the Single-Unit system of FBs-PLC, where, besides the available main units , the available communication peripherals resources and I/O expansion resources are depict on the left and the right respectively.

For the I/O of FBS-PLC, it can achieve a maximum of 256 point digital input (DI), 256 point digital output (DO), 64 word numeric input (NI), and 64 word numeric output (NO). Combined with various special interface modules, it can directly connect with devices such as Thermocouple, RTD, 7-segment LED display, and the Thumbwheel switch, which are shown on the right in the above figure.

Regarding communication resources, the FBs-PLC hardware can accommodate up to 5 communication ports (with a maximum speed of 921.6Kbps). In addition to providing the standard FATEK communication protocol, it also supports the Modbus master/slave protocol or any user-defined protocol. This functionality easily renders the connections with intelligent peripherals such as electronic scale, bar code reader, and various meters and gauges.

2.2 Formation of Multi-Unit System

By connections through communication ports and specific communication drivers, multiple Single-Unit PLC systems can be integrated to achieve resources sharing among multiple PLC or PLCs and its host computer. It is described as follows:

As shown in the figure, through the usage of high-speed RS-485 network, can easily establish the connections of 2~254

2.2.1 C

onnection of Multiple FBs-PLC (CPU Link)

RS-485網路

FBS-PLC

FBS-PLC

FBS-PLC

主機Main Unit

Main Unit 主機

主機Main Unit

Peripherals 週邊 I/O

Peripherals週邊 I/O

Peripherals週邊 I/O

main units (each PLC with its own station number). All need to do is to write and execute CPU Link commands in one of

the main units, which makes it the Master of the CPU Link network. No other command is necessary for other Slave units.

The Master CPU will automatically collect the information or data in the specific areas of all units (including the Master)

and put it into the Common Data areas(CDM) of all units. Thus all the units connected by network can share the data for

each other and turning the finite Single-Unit system with limited I/O into a huge system.

Telephone line

MODEM

MODEM

MODEM

FBS-PLC

FBS-PLC

FBS-PLC

Main Unit

Main Unit

Main Unit

Besides the above area network connection, FBs-PLC can also be connected using MODEM via the phone line (either

leased line or public phone line) to form remote multiple PLC Link. (When using a public phone line, the Master PLC

will perform consecutive dialing for all its Slave PLC.)

2.2.2 Connection of FBs-PLC with Host Computer or Intelligent Peripherals

Any one of the five communication ports on FBs-PLC can be used to connect to an upper-level computer or other systems, with this architecture, the FBs-PLC is playing the Slave role. FBs-PLC supports the FATEK and Modbus protocol. Connection can be established as long as the upper-level computer or intelligent peripherals use either one of the two protocols. In the application, in which driver for FATEK or Modbus is not available, FATEK also provide standard DDE communication server, which enables FBs-PLC to connect with any computer system supporting DDE. The following is the block diagram.

Computer上 位電 腦 Host 永宏通訊驅動程式(third party) 1 FATEK communication driver (third party) Modbus 通訊驅動程式(third party) DDE(FATEK Communication Sever)

FBS-PLC FBS-PLC FBS-PLC FBS-PLC FBS-PLC

Was this page helpful?

Tip: press ← → to switch chapters, Ctrl+K to search