Posted in

By

3 of 20Updated 2026-11-1724 min read中文版

Motion Parameters and Status

(Special Register and Relay)

This section will introduce the layout of memory in the M-PLC and the details of the register. The scope of Motion Registers starts from R36880 for using as the starting register, and the scope of Relays starts from M10512.

Type

Start Address

Size per axis or group

Motion System Register (word)

R

R36880

Motion Axis Register (word)

R

R36980

150

Motion System Relay (Bit)

M

M10512

Motion Axis Relay (Bit)

M

M10600

40

Motion Flow Block is done (Bit)

M

M12000

4096

Motion Flow Block is in progress (Bit)

M

M16160

4096

2-1 Motion Flow_ Special Register

※Described below are the current axis number of N.

※Please refer to Chapter 17 – Motion Flow Alarm for the description of error codes of each register and relay.

R Register

Register No.

Function

System Tag Symbol

R36880

Motion controller state

UNIT_STATE

R36881

Motion controller error code

UNIT_ERR

R36882

Unit Program State

UNIT_PROGRAM_STATE

R36883

Unit Error Code

UNIT_ERR_CODE

R36884 – 36903

Current Step

CURRENT_STEP_1 – CURRENT_STEP_20

R36904 – 36923

Current Block State

CURRENT_BLOCK_STATE_1 – CURRENT_BLOCK_STATE_20

R36924 – 36943

Flow State ID

FLOW_STATE_ID_1 – FLOW_STATE_ID_20

DR36964 – 36970

Encoder value

ENCODER_VALUE_2 – ENCODER_VALUE_4

DR36972

Gray code encoder value

GRAY_CODE_ENCODER_VALUE

DR36974

Gray code encoder turns

GRAY_CODE_ENCODER_TURNS

R36880 Motion Controller Status:

  • Status of Motion Control Card, the normal will be 0.
  • Display a number when function 187 fails to activate Motion.
  • Display a number when there is an EtherCAT communication abnormality during the motion process.
  • Display a number when a significant abnormality occurs during the motion process.

R36881 Motion Controller Error Code:

  • Error codes of Motion Control Card, the normal will be 0.
  • Display the error codes when Motion controller status is not 0.

R36882 Motion Program Status:

  • Displaying status after enabling Motion function.
  • The value is the maximum value within the motion flow states (R36924 – 36943).
  • 0 : Motion is not started.

4:Motion activated, EtherCAT connection in progress.

6:Motion flow control in progress.

9:Motion flow in error

R36883 Motoin Program Error Code:

  • The value is the error code of the last occurrence within the motion flow states (R36924 – 36933)

R36884 – 36903 Motion Branch Flow Block Number:

  • Current floe block number of Motion branch.
  • When a new motion flow is initiated or the motion flow enters a parallel branch, the foremost idle branch will be utilized.

R36904 – 36923 Motion Branch Flow Block Status:

  • Current flow block status of Motion branch.
  • 0:Idle branch

1:Flow block in control

2:Flow block completed

R36924 – 36943 Motoin Flow Status:

  • Status codes of Motion flow.
  • After Function 187 initiates the Motion, set it to 4
  • 0 : Motion is not started

4:Motion activated, EtherCAT connection in progress.

6:Motion flow control in progress.

9:Motion flow in error

DR36964 – 36970 External Encoder Value:

  • HSC 4 – HSC 7 Pulse Counts.
  • Need to enable HSC 4 – HSC 7 in the I/O configuration settings

DR36972 Gray Code Encoder Value:

  • Value of gray code encoder.
  • There are 8 bits for X8 – X15, with a range of 0 to 255.

DR36974 Gray Code Encoder Turns:

  • Turns of gray code encoder , with positive and negative signs.

2-2 Motion Control Special Relay

When setting the bit for motion control special register, each axis will be added with 40 bits. For example, if the HOME sensor of Axis-1 is M10605, then the HOME sensor of Axis-2 will become M10645, and so on.

Relay No.

Function

System Tag Symbol

M10520

All axes: Servo ON

ALL_SERVO_ON

M10521

All axes: Servo Reset

ALL_SERVO_FAULT_RST

M10522

Write all mapping parameters during initialization.

MAPPING_ALL_PARM_AFTER_INIT

M10523

Motion control card restart.

RESTART_MOTION_CARD

M10524

Custom PDO packet for special registers

ENABLE_CUSTOM_PDO

M10600 + 40*(n-1)

Axis control command: Servo ON

SERVO_ON

M10601+ 40*(n-1)

Axis control command: Fault Reset

FAULT_RST

M10602+ 40*(n-1)

Axis control command: Deceleration Stop

DEC_STOP

M10603+ 40*(n-1)

Axis control command: Emergency stop

EMG_STOP

M10604+ 40*(n-1)

Axis Synchronous main clutch ON

SYNC_MAIN_CLU_ON

M10605+ 40*(n-1)

Axis Origin On

ORIG_SIG_IN

M10606+ 40*(n-1)

Axis limit(+) on

LIM_POS_IN

M10607+ 40*(n-1)

Axis limit(-) on

LIM_NEG_IN

M10608+ 40*(n-1)

Z Count Signal

Z_SIG_IN

M10609+ 40*(n-1)

Axis Synchronous main clutch ON Disable

SYNC_MAIN_CLU_ON_DIS

M10610+ 40*(n-1)

Axis Synchronous main clutch OFF Disable

SYNC_MAIN_CLU_OFF_DIS

M10611+ 40*(n-1)

Axis Synchronous auxiliary clutch ON

SYNC_AUX_CLU_ON

M10612+ 40*(n-1)

Axis Synchronous auxiliary clutch ON Disable

SYNC_AUX_CLU_ON_DIS

M10613+ 40*(n-1)

Axis Synchronous auxiliary clutch OFF Disable

SYNC_AUX_CLU_OFF_DIS

M10614+ 40*(n-1)

Reserved

M10615+ 40*(n-1)

Axis Positive JOG

JOG_POS

M10616+ 40*(n-1)

Axis Negative JOG

JOG_NEG

M10617+ 40*(n-1)

Axis Probe 1 Function ON

PROBE1_EN

M10618+ 40*(n-1)

Axis Probe 1 Function Reset

PROBE1_RST

M10619+ 40*(n-1)

Axis Probe 2 Function ON

PROBE2_EN

M10620+ 40*(n-1)

Axis Probe 2 Function Reset

PROBE2_RST

M10621+ 40*(n-1)

Axis Synchronization Parameter Immediate Effect Request

SYNC_PARM_UP_IMMED

M10622+ 40*(n-1)

Axis Synchronization Parameter Next Period Effect Request

SYNC_PARM_UP_NEXT

M10623+ 40*(n-1)

Axis Synchronization Clutch Edge Trigger Buffer On

SYNC_MAIN_CLU_BUF_ON

M10624+ 40*(n-1)

Initialization of the Cam phase when the axis synchronous clutch is OFF

ECAM_PHASE_RST

M10625+ 40*(n-1)

Axis Rotation Angle Choose Near

ROT_ANG_NEAR

M10626+ 40*(n-1)

Axis Rotation Angle Target Direction

ROT_ANG_DIR

M10627+ 40*(n-1)

Axis Synchronization Mode ON

SYNC_MODE_ON

M10628+ 40*(n-1)

Pause Current Action

PAUSE_ON

M10629+ 40*(n-1)

High speed homing mode ON

HOM_SKIP_EN

M10630+ 40*(n-1)

Axis specifies current coordinates

SET_CUR_COOR

M10631+ 40*(n-1)

Axis operation mode ON

ADV_MODE_ON

M10632+ 40*(n-1)

Axis operation mode unit

ADV_MODE_UNIT_PLS

M10633+ 40*(n-1)

Axis operation mode absolute coordinates

ADV_MODE_COOR_ABS_OR_REF_MASK

M10634+40*(n-1)

Main clutch phase in/out display

MAIN_CLUTCH_PHASE_INOUT_DISPLAY

M10635+40*(n-1)

Axis skips the current control

MOV_CTRL_SKIP

M11240 + 40*(n-1)

Servo On

IS_SERVO_ON

M11241+ 40*(n-1)

Operation Ready

IS_OP_READY

M11242+ 40*(n-1)

Axis error in progress

IS_ERR

M11243+ 40*(n-1)

Axis warning in progress

IS_WARN

M11244+ 40*(n-1)

Control in progress

IS_CTRL

M11245+ 40*(n-1)

Homing in progress

IS_HOM_ACT

M11246+ 40*(n-1)

Homing done

IS_HOM_DN

M11247+ 40*(n-1)

Positioning in progress

IS_MOV_ACT

M11248+ 40*(n-1)

Positioning done

IS_MOV_DN

M11249+ 40*(n-1)

JOG in progress

IS_JOG_ACT

M11250+ 40*(n-1)

JOG done

IS_JOG_DN

M11251+ 40*(n-1)

Synchronizing in progress

IS_SYNC_ACT

M11252+ 40*(n-1)

Synchronizing done

IS_SYNC_DN

M11253+ 40*(n-1)

Speed mode in progress

IS_VEL_ACT

M11254+ 40*(n-1)

Speed mode done

IS_VEL_DN

M11255+ 40*(n-1)

Torque mode in progress

IS_TORQ_ACT

M11256+ 40*(n-1)

Torque mode done

IS_TORQ_DN

M11257+ 40*(n-1)

Axis soft limit(+) status

IS_SOFT_LIM_POS

M11258+ 40*(n-1)

Axis soft limit(-) status

IS_SOFT_LIM_NEG

M11259+ 40*(n-1)

Axis origin limit status

IS_ORIG_SIG

M11260+ 40*(n-1)

Axis limit(+) status

IS_LIM_POS

M11261+ 40*(n-1)

Axis limit(-) status

IS_LIM_NEG

M11262+ 40*(n-1)

Axis Probe 1 triggered

state

IS_PROBE1_TRIG

M11263+ 40*(n-1)

Axis Probe 2 triggered

state

IS_PROBE2_TRIG

M11264+ 40*(n-1)

Axis synchronization parameter effective state

IS_SYNC_PARM_UPDN

M11265+ 40*(n-1)

Axis tracking error state

IS_FOLLOW_ERR

M11266+ 40*(n-1)

Axis Pause Status

IS_PAUSE

M11267+ 40*(n-1)

Homing mode Z-phase signal

IS_Z_SIG

M11268+ 40*(n-1)

Axis operation mode action

IS_ADV_ACT

M11269+ 40*(n-1)

Axis operation mode done

IS_ADV_DN

Motion control special temporary register R + 150 per axis. For example, axis 1 position control state R36980, axis 2 position control state R37130, and so on.

Relay No.

Function

System Tag Symbol

R36980 + 150*(n-1)

Axis properties (Real axis or virtual axis)

TYPE

R36984+ 150*(n-1)

Current Control Mode

CTRL_MODE

R37004+ 150*(n-1)

Error Detail Information 1

ERR_INFO_1

R37005+ 150*(n-1)

Error Detail Information 2

ERR_INFO_2

R37006+ 150*(n-1)

Warning Detail Information 1

WARN_INFO_1

R37007+ 150*(n-1)

Warning Detail Information 2

WARN_INFO_2

R37012+ 150*(n-1)

Axis Control

CTRL_STATUS

R37013+ 150*(n-1)

Axis Warning Code

WARN_STATUS

DR37014+ 150*(n-1)

Command Coordinate

CMD_COOR

DR37016+ 150*(n-1)

Command Speed

CMD_VEL

DR37018+ 150*(n-1)

Command Position

CMD_PLS

R37020+ 150*(n-1)

Positioning Current Point No.

CUR_PT_OR_ECAM_NUM

DR37021+ 150*(n-1)

Current Coordinate

CUR_COOR

DR37023+ 150*(n-1)

Feedback Speed Monitor

CUR_VEL

DR37025+ 150*(n-1)

Position Deviation Monitor

CUR_COOR_DEV

DR37027+ 150*(n-1)

Digital Input from Driver

SERVO_DI_VALUE

R37029+ 150*(n-1)

Current Flow ID

CUR_FLOW_NUM

DR37030+ 150*(n-1)

Contact Output

SYNC_CONT_OUT

R37032+ 150*(n-1)

Current Torque

CUR_TORQ

DR37033+ 150*(n-1)

E-Cam Input Phase

ECAM_IN_PHASE

DR37035+ 150*(n-1)

Origin Position

ORG_PLS

R37037 – R37039+ 150*(n-1)

Axis Status Word 1-3

CONTROL_STATUS_WORD1

DR37040+ 150*(n-1)

Main Clutch Output Phase

MAIN_CLU_INOUT_PHASE

DR37042+ 150*(n-1)

Probe 1 Coordinate

PROBE1_COOR

DR37044+ 150*(n-1)

Probe 2 Coordinate

PROBE2_COOR

DR37050+ 150*(n-1)

Axis specifies coordinates

SET_COOR_VALUE

DR37052+ 150*(n-1)

Axis advanced control mode

SET_ADV_MODE

DR37054+ 150*(n-1)

Axis advanced mode instruction 1

SET_ADV_CMD

DR37056+ 150*(n-1)

Axis advanced mode instruction 2

SET_ADV_CMD2

DR37058+ 150*(n-1)

Axis advanced mode instruction 3

SET_ADV_CMD3

DR37060+ 150*(n-1)

Axis advanced mode instruction 4

SET_ADV_CMD4

DR37062+ 150*(n-1)

Axis advanced mode instruction 5

SET_ADV_CMD5

DR37064+ 150*(n-1)

Axis advanced mode instruction 6

SET_ADV_CMD6

DR37066+ 150*(n-1)

Axis advanced mode instruction 7

SET_ADV_CMD7

M10520 All axes servo on:

  • Rising: All axis servo on
  • Falling: All axis servo off
  • Axis enabled (M10600+40*(n-1)) will also change accordingly.

M10521 All axis servo reset:

  • Rising: All axis clearing error
  • 1.The motion program status (R36882) should change from 9 to 4 or 6, and (R36924 – R36933) should change from 9 to 4

2. The motion program error code (R36883) should change to 0.

3. If there is an error in the drive, it should be cleared at the same time.

4. Axis Error Info (R37004 + 150*(n-1)) and (R37005 + 150*(n-1)) should change to 0.

5. Axis Alarm Info (R37006 + 150*(n-1)) and (R37007 + 150*(n-1)) should change to 0.

6. Axis Status is in error (M11242 + 40*(n-1)) and Error Status is in alarm (M11243 + 40*(n-1)) should be reset.

M10522 Write all mapping parameters during initialization.:

  • On: Complete write during initialization.
  • Off: Write according to the mapping table settings.
  • Enable:Synchronously write all items from the mapping table after Fun187 is executed and completed.
  • Not enable:Write the items according to the mapping table settings after Fun187 is executed and completed.

M10523 Motion control card restart.:

  • Rising: Restart the motion control card.
  • Enable:Cease all current motion control and restore to the status at PLC restart.
  • When encountering a system emergency stop, it can be used to restart the motion control card.

M10524 Custom PDO packet for special registers:

  • Enable: Use special registers
  • When enabled, use R37050~R37081 + 150*(n-1) as the EtherCAT PDO packet.

M10600 + 40*(n-1) Axis control command Servo ON:

  • Rising: Single axis servo on
  • Falling: Single axis servo off
  • Will change accordingly when all axes servo on (M10520) changes.

M10601 + 40*(n-1) Axis control command Fault Reset:

  • Rising: Single axis clearing error
  • Motoin flow status (R36924 – R36933) of current axis motion flow No. (R37029) should change from 9 to 4.

2. If there is an error in the drive, it should be cleared at the same time.

3. Axis Error Info (R37004 + 150*(n-1)) and (R37005 + 150*(n-1)) should change to 0.

4. Axis Alarm Info (R37006 + 150*(n-1)) and (R37007 + 150*(n-1)) should change to 0.

5. Axis Status is in error (M11242 + 40*(n-1)) and Error Status is in alarm (M11243 + 40*(n-1)) should be reset.

M10602 + 40*(n-1) Axis deceleration stop:

  • Rising: Single axis deceleration stop.
  • Using the stop mode from the axis table to stop axis and deceleration uses the deceleration setting value from the axis table.
  • Trigger axis stop warning.

M10603 + 40*(n-1) Axis emergency stop:

  • Rising: Single axis emergency stop
  • Trigger axis stop warning

M10604 + 40*(n-1) Axis Synchronous main clutch ON:

  • High: On
  • Low: Off
  • Enable:Set by clutch ON condition in sync parameters.

M10605 + 40*(n-1) Axis origin on:

  • High: On
  • Low: Off
  • Enable:Set by homing IO source in motion axis parameters.
  • The axis origin limit status (M11259 + 40*(n-1)) should change accordingly.

M10606 + 40*(n-1) Axis limit(+) on:

  • High: On
  • Low: Off
  • Enable:Set by homing IO source in motion axis parameters.
  • The axis limit(+) status (M11260 + 40*(n-1)) should change accordingly.

M10607 + 40*(n-1) Axis limit(-) on:

  • High: On
  • Low: Off
  • Enable:Set by homing IO source in motion axis parameters.
  • The axis limit(-) status (M11261 + 40*(n-1)) should change accordingly

M10608 + 40*(n-1) Z Count Signal:

  • High: On
  • Low: Off
  • Enable:Set by homing IO source in motion axis parameters.

M10609 + 40*(n-1) Axis Synchronous main clutch ON Disable:

  • High: On
  • Low: Off
  • Enable:Does not act when axis sync main clutch ON condition is met.

M10610 + 40*(n-1) Axis Synchronous main clutch OFF Disable:

  • High: On
  • Low: Off
  • Enable:Does not act when axis sync main clutch OFF condition is met.

M10611 + 40*(n-1) Axis Synchronous auxiliary clutch ON:

  • High: On
  • Low: Off
  • Enable:Set by auxiliary clutch on condition in sync parameter.

M10612 + 40*(n-1) Axis Synchronous auxiliary clutch ON Disable:

  • High: On
  • Low: Off
  • Enable:Does not act when axis sync aux clutch ON condition is met.

M10613 + 40*(n-1) Axis Synchronous auxiliary clutch OFF Disable:

  • High: On
  • Low: Off
  • Enable:Does not act when axis sync aux clutch OFF condition is met

M10615 + 40*(n-1) Axis Positive JOG:

  • High: On
  • Low: Off
  • Rising edge triggers positive direction jogging. If in negative direction jogging mode, it will switch to positive direction jogging
  • The speed follows the axis table JOG speed

M10616 + 40*(n-1) Axis Negative JOG:

  • High: On
  • Low: Off
  • Rising edge triggers negative direction jogging. If in positive direction jogging mode, it will switch to negative direction jogging
  • The speed follows the axis table JOG speed

M10617 + 40*(n-1) Axis Probe 1 on:

  • Enable:Enable the drive probe 1 function.
  • When the probe is triggered, set the trigger status of axis probe 1 (M11262 + 40*(n-1)) to ON, and the axis driver probe 1 coordinates (DR37042 + 150*(n-1)) value will be updated.

M10618 + 40*(n-1) Axis Probe 1 Function Reset:

  • Rising Trigger
  • When triggered on the rising edge, the trigger status of axis probe 1 (M11262 + 40*(n-1)) will be reset to OFF.

M10619 + 40*(n-1) Axis Probe 2 on:

  • Enable:Enable the drive probe 2 function.
  • When the probe is triggered, set the trigger status of axis probe 2 (M11263 + 40*(n-1)) to ON, and the axis driver probe 2 coordinates (DR37044 + 150*(n-1)) value will be updated.

M10620 + 40*(n-1) Axis Probe 2 Function Reset:

  • Rising Trigger
  • When triggered on the rising edge, the trigger status of axis probe 2 (M11263 + 40*(n-1)) will be reset to OFF.

M10621 + 40*(n-1) Axis Synchronization Parameter Immediate Effect Request:

  • High: On
  • Low: Off
  • Enable:Immediately update the sync parameters to the axis in synchronous control.

M10622 + 40*(n-1) Axis Synchronization Parameter Next Period Effect Request:

  • High: On
  • Low: Off
  • Enable:At the beginning of the next cam cycle, update the sync parameters to the axis in sync control.

M10623 + 40*(n-1) Axis Synchronization Clutch Edge Trigger Buffer On:

  • High: On
  • Low: Off
  • Enable:When the clutch ON is set as edge-triggered, the caching function takes effect.

M10624 + 40*(n-1) Initialization of the Cam phase when the axis synchronous clutch is OFF:

  • High: On
  • Low: Off
  • Enable:When the clutch is OFF, set the phase between the master clutch output end and the cam to the default value.

M10625 + 40*(n-1) Axis rotation angle choose near:

  • High: Off
  • Low: On
  • When the command is in absolute coordinates, it is determined based on axis rotation angle choose near (M10625 + 40*(n-1)) and axis rotation angle target direction (M10626 + 40*(n-1)) .
  • (High) Off:Approach the target angle in axis rotation angle target direction (M10626 + 40*(n-1)) .
  • (Low) On:When the unit is set to display in 360 degrees, choose the nearest direction for the target position.

M10626 + 40*(n-1) Axis rotation angle target direction:

  • High: +
  • Low: –
  • Positive direction: Always approach the target angle in the positive direction.
  • Negative direction: Always approach the target angle in the negative direction.

M10627 + 40*(n-1) Axis Synchronization Mode ON:

  • High: On
  • Low: Off
  • On:Setting the axis to sync control, if the axis is not in free control, it will trigger an axis occupancy alarm.
  • Off:Axis exits sync mode, but if there is deceleration stop in sync parameters, it must wait for the deceleration completion before setting the axis to free control.

M10628 + 40*(n-1) Axis pauses current action:

  • High: On
  • Low: Off
  • On:Pause the current action, and the action issued after the pause will be executed once the pause is released.
  • Off:Continue with the current action.

M10629 + 40*(n-1) High speed homing mode ON:

  • High: On
  • Low: Off
  • On:No longer need to approach the home position at creeping velocity in homing mode.

M10630 + 40*(n-1) Axis specifies current coordinates:

  • Rising Trigger
  • When the rising edge is triggered, the value of the special register DR37050 will be set to the current coordinate.
  • Only be used in axis uncontrolled or synchronous mode.
  • Must be used when M10524 custom PDO packet is not enabled.

M10631 + 40*(n-1) Axis advanced mode ON:

  • High: On
  • Low: Off
  • Must be used when M10524 custom PDO packet is not enabled.
  • Only be used under the synchronous mode.
  • The value of special register DR37052 is regarded as the control mode: 0 for no control, 1 for position control, 2 for speed control, and 3 for torque control.
  • When switching control modes, it is necessary to toggle M10631 again or set DR37052 to 0 (no control) state
  • The value of special register DR37054 is considered as the control command.
  • When the mode is speed mode or torque mode, the value of special register DR37056 is considered as the torque limit or speed limit.
  • The default units are as follows:

Position mode:axis coordinate units

Speed mode:axis coordinate units per second

Torque mode:0.1%.

  • Can pre-enable M10632 to specify the units as follows:

Position mode:PLS (Pulse)

Speed mode:PLS/s (Pulse per second)

Torque mode:0.1%.

M10632 + 40*(n-1) Axis advanced mode unit:

  • High: Pulse Unit
  • Low: Axis Table Unit
  • Pulse Unit:

Position mode:axis coordinate units

Speed mode:axis coordinate units per second

Torque mode:0.1%.

  • Axis Table Unit:The decimal point position refers to the number of decimal places set on the motion axis table.

M10633 + 40*(n-1) Axis advanced mode absolute coordinates:

  • High: absolute coordinate
  • Low: relative coordinate
  • Absolute coordinates: Start at the origin position.
  • Relative coordinates: Start at the position triggered by M10631.
  • When M10631 is set to high, the modification is ineffective.

M10634 + 40*(n-1) Main clutch phase inout display:

  • High bit: Input phase
  • Low bit: Output phase
  • Select whether the clutch phase displayed by DR37040 is the input phase or the output phase.

M10635 + 40*(n-1) Axis skips the current control:

  • Rising Edge: Skip the current control.
  • When triggered on the rising edge, the current control is terminated, and the motion flow proceeds to the next process block.

M11240 + 40*(n-1) Axis servo on:

  • High: Servo on
  • Low: Servo off
  • Should change after M10520 or M10600+40*(n-1) trigger.

M11241 + 40*(n-1) Operation Ready:

  • High: Done preparing
  • Low: Still preparing
  • Should change after function 187 activate Motion .
  • When unchanged, status codes should be visible in R36880 and R36881.

M11242 + 40*(n-1) Axis error in progress:

  • High: In error
  • Low: No error
  • The axis should stop.
  • Error info should be visible in R37004 + 150*(n-1) and R37005 + 150*(n-1) .
  • Can use M10521 or M10601 + 40*(n-1) to reset.

M11243 + 40*(n-1) Axis warning in progress:

  • High: In alarm
  • Low: No alarm
  • The axis will not stop.
  • Alarm info should be visible in R37006 + 150*(n-1) and R37007 + 150*(n-1) .
  • Can use M10521 or M10601 + 40*(n-1) to reset.

M11244 + 40*(n-1) Control in progress:

  • High: In control
  • Low: No control
  • When current axis control mode (R36984 + 150*(n-1)) has a value, set it to the high bit.
  • After completion, set it to the low bit.

M11245 + 40*(n-1) Homing in progress:

  • High: In HOME Return mode
  • Low: HOME Return mode is complete
  • When current axis control mode (R36984 + 150*(n-1)) displays as the homing mode, set it to the high bit.
  • After completion, set it to the low bit.

M11246 + 40*(n-1) Homing done:

  • High: HOME Return mode is complete
  • Reset:To be reset when Axis HOME Returing (M11245 + 40*(n-1)) in the high bit.

M11247 + 40*(n-1) Positioning in progress:

  • High: In Positioning mode
  • Low: Positioning mode is complete
  • When current axis control mode (R36984 + 150*(n-1)) displays as the position control mode, set it to the high bit.
  • After completion, set it to the low bit.

M11248 + 40*(n-1) Positioning done:

  • High: Positioning mode is complete
  • Reset:To be reset when in axis positioning mode (M11247 + 40*(n-1)) in the high bit

M11249 + 40*(n-1) JOG in progress:

  • High: In JOG mode
  • Low: JOG mode is complete
  • When current axis control mode (R36984 + 150*(n-1)) displays as the jogging mode, set it to the high bit.
  • After completion, set it to the low bit

M11250 + 40*(n-1) JOG done:

  • High: JOG mode is complete
  • Reset:To be reset when axis jogging (M11247 + 40*(n-1)) in the high bit.

M11251 + 40*(n-1) Synchronizing in progress:

  • High: Clutch connect / apart act
  • Low: Clutch connect / apart done
  • When main clutch ON / OFF connection method is set to sliding/following, set to the high bit during the connection process.
  • After completion, set it to the low bit.

M11252 + 40*(n-1) Sychronization done:

  • High: Clutch connect done
  • Low: Clutch apart done
  • The status of the axis synchronous master clutch ON / OFF.

M11253 + 40*(n-1) Speed mode in progress:

  • High: In Speed mode
  • Low: Speed mode is complete
  • When current axis control mode (R36984 + 150*(n-1)) displays as the speed mode, set it to the high bit.
  • After completion, set it to the low bit.

M11254 + 40*(n-1) Speed mode done:

  • High: Target speed reaxhed / Upper speed limit reached
  • 1.Speed mode reaches the target speed.

2.Torque mode reaches the speed limit.

M11255 + 40*(n-1) Torque mode in progress:

  • High: In Torque mode
  • Low: Torque mode is complete
  • When current axis control mode (R36984 + 150*(n-1)) displays as the torque mode, set it to the high bit.
  • After completion, set it to the low bit.

M11256 + 40*(n-1) Torque mode done:

  • High: Target torque reached / Upper torque limit reached
  • 1.Torque mode reaches the target speed.

2.Speed mode reaches the speed limit.

M11257 + 40*(n-1) Axis soft limit(+) status:

  • High: Status ON
  • Low: Status OFF
  • Display the current software limit status within Motion.

M11258 + 40*(n-1) Axis soft limit(-) status:

  • High: Status ON
  • Low: Status OFF
  • Display the current software limit status within Motion.

M11259 + 40*(n-1) Axis origin limit status:

  • High: Status ON
  • Low: Status OFF
  • Display the actual limit status received within Motion.

M11260 + 40*(n-1) Axis limit(+) status:

  • High: Status ON
  • Low: Status OFF
  • Display the actual limit status received within Motion.

M11261 + 40*(n-1) Axis limit(-) status:

  • High: Status ON
  • Low: Status OFF
  • Display the actual limit status received within Motion.

M11262 + 40*(n-1) Axis Probe 1 triggered state:

  • High: Status ON
  • Low: Status OFF
  • Display that servo probe 1 is triggered, and the axis drive probe 1 coordinate (DR37042 + 150*(n-1)) value will be updated.

M11263 + 40*(n-1) Axis Probe 2 triggered state:

  • High: Status ON
  • Low: Status OFF
  • Display that servo probe 2 is triggered, and the axis drive probe 2 coordinate (DR37044 + 150*(n-1)) value will be updated.

M11264 + 40*(n-1) Axis synchronization parameter effective state:

  • High: Valid
  • Display that sync parameters have been written to the axis in sync control.
  • Reset condition: When both the axis sync parameter apply immediately (M10621 + 40*(n-1)) and Axis sync parameter apply next period (M10622 + 40*(n-1)) are in the low state.

M11265 + 40*(n-1) Axis tracking error state:

  • High: Triggered
  • 1.Display whether the axis following error exceeds the axis following error window.
  • 2.Enable when the axis following error timeout is not zero.

M11266 + 40*(n-1) Axis pause status:

  • High: Paused.
  • Display whether the axis is currently in pause mode.

M11267 + 40*(n-1) Homing mode Z-phase signal:

  • High: Z-phase signal is triggered.
  • Display Motion internally actual received Z-phase signal status.

M11268 + 40*(n-1) Axis advanced mode action:

  • High: The advanced mode is in progress.
  • Low: Advanced mode completed/left advanced mode
  • The axis advanced mode is in progress.

M11269 + 40*(n-1) Axis advanced mode done:

  • High: Advanced mode completed.
  • Low: The advanced mode is in progress /left advanced mode
  • Advanced mode completed.

R36980+ 150*(n-1) Axis Attribute:

  • Display the actual axis as real or virtual axis.
  • Configured through motion network links or modified by Function 235.
  • 0:Not used

1:Actual axis

2:Virtual axis

R36984+ 150*(n-1) Current Axis Control Mode:

  • Display current control mode.
  • After ending any control mode, it should return to 0.
  • 0:Not controled

1:Position control mode

2:Homing mode

3:Jogging mode

4:Speed mode

5:Torque mode

6:Sync control mode

R37004+ 150*(n-1) Axis Error Info 1:

  • Display axis error number.
  • Can be cleared by M10521 (reset all axes) or M10601 + 40*(n-1) (reset an axis).
  • Refer to the alarm list for error codes.

R37005+ 150*(n-1) Axis Error Info 2:

  • Display current axis error flow block number.
  • Can be cleared by M10521 (reset all axes) or M10601 + 40*(n-1) (reset an axis).
  • Refer to the alarm list for error codes.

R37006+ 150*(n-1) Axis Alarm Info 1:

  • Display axis alarm number.
  • Can be cleared by M10521 (reset all axes) or M10601 + 40*(n-1) (reset an axis).
  • Refer to the alarm list for error codes.

R37007+ 150*(n-1) Axis Alarm Info 2:

  • Display current axis alarming flow block number.
  • Can be cleared by M10521 (reset all axes) or M10601 + 40*(n-1) (reset an axis).
  • Refer to the alarm list for error codes.

R37012+ 150*(n-1) Axis in control:

  • Display axis is in control.
  • Same as M11244 + 40*(n-1) .

R37013+ 150*(n-1) Axis in alarm:

  • Display axis is in alarm.
  • 0:Not in alarm.

1:In warning,same as M11243 + 40*(n-1) .

2:In error,same as M11242 + 40*(n-1) .

DR37014+ 150*(n-1) Axis Command Coordinates:

  • Display the coordinate command calculated by the controller for axis.
  • Reciprocal coordinate transformation relationship with axis command position (DR37018 + 150*(n-1)) .
  • Includes decimal places, determined by the decimal point position in the motion axis settings (axis table) parameters.

DR37016+ 150*(n-1) Axis Command Speed:

  • Position, HOME, Jogging, Synchronous Mode: Change rate of command coordinate (DR37014) .
  • Speed Mode: Displays the speed command of the controller for the axis.
  • Torque Mode: Meaningless.
  • Includes decimal places, determined by the decimal point position in the motion axis settings (axis table) parameters.

DR37018+ 150*(n-1) Axis Command Position:

  • Display the controller’s (pulse) position command for this axis.
  • Units are pulses.
  • The drive end should receive the same value.

R37020+ 150*(n-1) Current Axis Controlling Point No.:

  • Display the current control point number of position mode.
  • Display the current cam number of sync mode.
  • Should be the motion point number (motion point table) identifier.
  • In the case of continuous points, it will display the number of the previous point when traveling along a continuous path between two points.

DR37021+ 150*(n-1) Current Axis Coordinates:

  • Display the actual axis coordinate.
  • The displayed value is obtained by performing coordinate conversion on the position (pulse) value feedback from the driver end.
  • The displayed value is obtained by coordinate transformation from the feedback position (pulse) value received at the drive end.
  • Includes decimal places, determined by the decimal point position in the motion axis settings (axis table) parameters.

DR37023+ 150*(n-1) Axis feedback speed:

  • Display the actual axis speed.
  • Feedback speed from the drive end.
  • The unit of the feedback speed at the drive end should be filled in with the velocity unit and velocity gain set in the unit settings of the motion axis (axis table) parameters.

DR37025+ 150*(n-1) Axis p.osition deviation monitor:

  • Display axis position deviation.
  • This value is equal to the axis commanded position (DR37014) minus current axis position (DR37021) .
  • Reference the following error in the operational setting of the motion axis configuration (axis table) parameters.

DR37027+ 150*(n-1) Axis Driver Digital Input:

  • Display the digital input value of the axis driver feedback.
  • The definition of each bit is determined by the driver.

R37029+ 150*(n-1) Current Axis Motion Flow No.:

  • Display the motion flow number of the current control axis.
  • 0 when there is no control or when using ladder instructions.

DR37030+ 150*(n-1) Axis contact output:

  • Display axis contact output status.
  • The current axis control mode (R36984) needs to be in sync control.
  • The axis contact output is only effective when the current axis control mode (R36984) is in sync control, and synch control requires the use of E-Cam, that is., the cam data number in the synch parameters is not 0.
  • The axis electronic cam input phase (DR37033) can be compared with the axis contact output.

R37032+ 150*(n-1) Current Axis Torque:

  • Display the torque feedback from the axis driver.
  • Units are 0.1% .

DR37033+ 150*(n-1) Axis Electronic Cam Input Phase:

  • Display the input phase of the axis-synchronized electronic cam.
  • The axis electronic cam input phase is only effective when the current axis control mode (R36984) is in sync control.
  • The range of axis electronic cam input phase is from 0 to the input axis period in sync parameters.

DR37035+ 150*(n-1) Axis HOME Position:

  • Display the HOME (pulse) position of the axis.
  • Should be power-off hold.

R37037 – R37039+ 150*(n-1) Axis control status words:

  • Display axis control status words.
  • The bit status from axis status enable (M11240 + 40*(n-1)) to axis pause status (M11266 + 40*(n-1)).

DR37040+ 150*(n-1) Axis main clutch output phase:

  • Display the output phase of the axis sync main clutch.
  • The axis main clutch output phase is only effective when the current axis control mode (R36984) is in sync control.
  • The range of axis main clutch output phase is from 0 to the input axis period in sync parameters.

DR37042+ 150*(n-1) Axis Driver Probe 1 Coordinates:

  • Display the coordinate of probe 1 from axis driver feedback.
  • When axis probe 1 on (M10617 + 40*(n-1)) is triggered, trigger status of axis probe 1 (M11262 + 40*(n-1)) is set to ON.

DR37044+ 150*(n-1) Axis Driver Probe 2 Coordinates:

  • Display the coordinate of probe 2 from axis driver feedback.
  • When axis probe 2 on (M10619 + 40*(n-1)) is triggered, trigger status of axis probe 2 (M11263 + 40*(n-1)) is set to ON.

DR37050+ 150*(n-1) Axis specifies coordinates:

  • The unit is the same as the motion axis table unit, and the decimal point corresponds to the number of decimal places on the motion axis table.
  • When M10630 axis specifies the current coordinate, set DR37050 to the current coordinate.

DR37052+ 150*(n-1) Axis advanced control mode:

  • The value of special register DR37052 is regarded as the control mode: 0 for no control, 1 for position control, 2 for speed control, and 3 for torque control.
  • When switching control modes, it is necessary to toggle M10631 again or set DR37052 to 0 (no control) state.

DR37054+ 150*(n-1) Axis advanced mode instruction 1:

  • In position and speed modes, the unit is the same as the motion axis table unit, and the decimal point corresponds to the number of decimal places on the motion axis table.
  • The unit can be switched to PLS, PLS/s using M10632.
  • In torque mode, the unit is fixed at 0.1%.

DR37056+ 150*(n-1) Axis advanced mode instruction 2:

  • In position mode, it represents the maximum speed, with units in coordinate units per second (coordinate unit/s), or can be switched to PLS/s using M10632.
  • In speed mode, it represents the torque limit, with units at 0.1%.
  • In torque mode, it represents the speed limit, with units in RPM.

DR37058+ 150*(n-1) Axis advanced mode instruction 3:

  • In position mode, it represents the maximum acceleration/deceleration, with units in coordinate units per second squared (coordinate unit/s^2), or can be switched to PLS/s^2 using M10632.

DR37060+ 150*(n-1) Axis advanced mode instruction 4:

  • In position mode, it represents maximum deceleration, with units in coordinate units/s^2, or switched to PLS/s^2 using M10632. When set to 0, it indicates that maximum acceleration = maximum deceleration.
  • In external input positioning mode, it represents maximum deceleration, with units in coordinate units/s^2, or switched to PLS/s^2 using M10632.

DR37062+ 150*(n-1) Axis advanced mode instruction 5:

  • In external input positioning mode, it represents the input source: 0 for Gray code, 1~8 for HSC0~HSC7.
  • In external input positioning mode, it represents the input source: 101~116 for axis command coordinates.

DR37064+ 150*(n-1) Axis advanced mode instruction 6:

  • In external input positioning mode, it represents the numerator for coordinate transformation.

DR37066+ 150*(n-1) Axis advanced mode instruction 7:

  • In external input positioning mode, it represents the denominator for coordinate transformation.
Was this page helpful?

Tip: press ← → to switch chapters, Ctrl+K to search