Posted in

By

4 of 9Updated 2026-11-1712 min read中文版

3-1 Sequential Instructions

Operand

Symbol

Function

Instruction Type

X,Y,M,

S,T,C

Starting a network with a normally open (A) contact

Network starting

instructions

Starting a network with a normally closed (B) contact

Starting a network with a differential up (TU) contact

Starting a network with a differential down (TD) contact

Starting a network with a open circuit contact

Starting a network with a short circuit contact

X,Y,M,

S,T,C

Starting a relay circuit from origin or branch

line with a normally open contact

Origin or branch line starting instructions

Starting a relay circuit from origin or branch

line with a normally closed contact

Starting a relay circuit from origin or branch

line with a differential up contact

Starting a relay circuit from origin or branch

line with a differential down contact

Starting a relay circuit from origin or branch

line with a open circuit contact

Starting a relay circuit from origin or branch

line with a short circuit contact

X,Y,M,

S,T,C

Serial connection of normally open contact

Serial connection instructions

Serial connection of normally close contact

Serial connection of differential up contact

Serial connection of differential down contact

Serial connection of open circuit contact

Serial connection of short circuit contact

X,Y,M,

S,T,C

Parallel connection of normally open contact

Parallel connection instructions

Parallel connection of normally closed contact

Parallel connection of differential up contact

Parallel connection of differential down contact

Parallel connection of open circuit contact

Parallel connection of short circuit contact

Serial connection of two circuit blocks

Blocks merge instructions

Parallel connection of two circuit blocks

Y,M,S

Send result to coil

Coil output instruction

Send inverted result to coil

Y

Send result to an external output coil and appoint it as of retentive type

TR

Save the node status to a temporary relay

Node operation instruction

Load the temporary relay

Take the transition up of the node status

Take the transition down of the node status

Invert the node status

Set a coil

Reset a coil

sequential instructions list

※The 36 sequential instructions listed above are all applicable to every models of M – SERIES PLC.

3-2 Function Instructions

There are more than 200 different M PLC function instructions. If put the D and P derivative instructions into account, the total number of instructions is over 300. On top of these, many function instructions have multiple input controls (up to 8 inputs) which can have up to 8 different types of operation mode combinations. Hence, the size of M PLC instruction sets is in fact not smaller than that of a large PLC. Having powerful instruction functions, though may help for establishing the complicated control applications, but also may impose a heavy burden on those users of small type PLC’s. For ease of use, M-Series PLC function instructions are divided into two groups, the Basic function group (The instructions attached with “★” symbol are basic functions which amounts to 26 function instructions and 4 SFC instructions) and the advanced function group.

  • Timer/Counter Instructions

FUN

No

Name

Operand

Derivative Instruction

Function descriptions

★

T nnnn

PV

General timer instructions

( “nnnn” range 0~1023, total 1024)

★

C nnnn

PV

General counter instructions

( “nnnn” range 0~1279, total 1280)

★ 7

UDCTR

CV,PV

DP

16-Bit or 32-Bit up/down counter

Timer/Counter Instructions list

  • Output Operation Instructions

★ 4

DIFU

D

P

to get the up differentiation of a D relay and store the result to D

★ 5

DIFD

D

P

to get the down differentiation of a D relay and store the result to D

★10

TOGG

D

P

Toggle the ON/OFF status of the D relay

Output Operation Instructions List

  • Set/Reset Instructions

★

SET

D

DP

Set all bits of register or a discrete point to 1

★

RST

D

DP

Clear all bits of register or a discrete point to 0

Set/Reset Instructions List

  • SFC Instructions

★

STP

Snnnn

STEP declaration

★

STPEND

End of the STEP program

★

TO

Snnnn

STEP divergent instruction

★

FROM

Snnnn

STEP convergent instruction

SFC Instructions List

  • Arithmetic Instructions

★11

(+)

Sa,Sb,D

D P

Perform addition of Sa and Sb and then store the result to D

★12

(-)

Sa,Sb,D

D P

Perform subtraction of Sa and Sb and then store the result to D

★13

(*)

Sa,Sb,D

D P

Perform multiplication of Sa and Sb and then store the result to D

★14

(/)

Sa,Sb,D

D P

Perform division of Sa and Sb and then store the result to D

★15

(+1)

D

D P

Adds 1 to the D value

★16

(−1)

D

D P

Subtracts 1 from the D value

24

SUM

S,N,D

D P

Take the sum of the successive N values beginning from S and store it in D

25

MEAN

S,N,D

D P

Take the mean average of the successive N values beginning from S and store it in D

27

NEG

D

D P

Take the 2’s complement (negative number) of the D value and store it back in D

28

ABS

D

D P

Take the absolute value of D and store it back in D

31

CRC16

MD,S,N,D

P

CRC16 caculator

33

LCNV

Md,S,Ts,D,L

D P

Linear Conversion

34

MLC

Rs,SI,Tx,Ty,TI,D

P

Multiple Linear Conversion

200

I→F

S,D

D P

Integer to floating point number conversion

201

F→I

S,D

D P

Floating point number to integer conversion

202

FADD

Sa,Sb,D

P

Addition of floating point number

203

FSUB

Sa,Sb,D

P

Subtraction of floating point number

204

FMUL

Sa,Sb,D

P

Multiplication of floating point number

205

FDIV

Sa,Sb,D

P

Division of floating point number

206

FCMP

Sa,Sb

P

Comparison of floating point number and then store the result to FO0~FO2

207

FZCP

S,SU,SL

P

Comparison of floating point number S to the zones formed by the upper limit SU and the lower limit SL and then store the result to FO0~FO2

209

FSIN

S,D

P

SIN trigonometric function

210

FCOS

S,D

P

COS trigonometric function

211

FTAN

S,D

P

TAN trigonometric function

212

FNEG

D

P

Change sign of floating point number

213

FABS

D

P

Take absolute value of floating point number

218

FASIN

S,D,MD

P

Floating Point arc sine

219

FACOS

S,D,MD

P

Floating Point arc cosine

226

MOD

Sa,Sb,D

D P

Modulo (Remainder)

Arithmetic Instructions List

  • Logic Operation Instructions

★18

AND

Sa,Sb,D

D P

Perform logical AND for Sa and Sb and store the result to D

★19

OR

Sa,Sb,D

D P

Perform logical OR for Sa and Sb and store the result to D

35

XOR

Sa,Sb,D

D P

Take the result of the Exclusive OR logical operation made between Sa and Sb, and store it in D

36

XNR

Sa,Sb,D

D P

Take the result of the Exclusive NOR logical operation made between Sa and Sb, and store it in D

Logic Operation Instructions List

  • Comparison Instructions

★17

CMP

Sa,Sb

D P

Compare the data at Sa and data at Sb and store the result to FO0~FO2

37

ZNCMP

S,SU,SL

D P

Compare S with the zones formed by the upper limit SU and lower limit SL, and store the result to FO0~FO2

170

=

Sa,Sb

D

Equal to compare

171

>

Sa,Sb

D

Greater than compare

172

<

Sa,Sb

D

Less than compare

173

<>

Sa,Sb

D

Not equal to compare

174

>=

Sa,Sb

D

Greater than or equal to compare

175

=<

Sa,Sb

D

Less than or equal to compare

Comparison Instructions List

  • Data Movement Instructions

★ 8

MOV

S,D

D P

Transfer data from S to D

★ 9

MOV/

S,D

D P

Invert data S, and then transfers the result to D

40

BITRD

S,N

D P

Read the status of the bits specified by N within S, and send it to FO0

41

BITWR

D,N

D P

Write the INB input status into the bits specified by N within D

42

BITMV

S,Ns,D,Nd

D P

Write the status of bit specified by Ns within S into the bit specified by Nd within D

43

NBMV

S,Ns,D,Nd

D P

Write the Ns nibble within S to the Nd nibble within D

44

BYMV

S,Ns,D,Nd

D P

Write the byte specified by Ns within S to the byte specified by Nd within D

45

XCHG

Da,Db

D P

Exchange the values of Da and Db

46

SWAP

D

P

Swap the high-byte and low-byte of D

115

DBUF

ID,CH,D

Store the data form Expansion Module to PLC register

160

RWFR

Sa,Sb,Pr,L,Sa

Read/write file register commands

161

WR-MP

S,Bk,Os,Pr,L,WR

Write memory pack

162

RD-MP

Bk,Os,Pr,L,D

Read memory pack

Data Movement Instructions List

  • Shifting/Rotating Instructions

★ 6

BSHF

D

D P

shift left or right 1 bit of D register

51

SHFL

D,N

D P

Shift left the D register N bits and move the last shifted out bits to FO0. The empty bits will be replaced by INB input bit

52

SHFR

D,N

D P

Shift right the D register N bits and move the last shifted out bits to FO0. The empty bits will be replaced by INB input bit

53

ROTL

D,N

D P

Rotate left the D operand N bits and move the last rotated out bits to FO0

54

ROTR

D,N

D P

Rotate right the D operand N bits and move the last rotated out bits to FO0

Shifting/Rotating Instructions List

  • Code Conversion Instruction

20

→BCD

S,D

D P

Binary to BCD conversion

21

→BIN

S,D

D P

BCD to Binary conversion

33

LCNV

Md,S,Ts,D,L

D P

Linear conversion

34

MLC

Rs,SI,Tx,Ty,TI,D

P

Multiple linear conversion

55

B→G

S,D

D P

Binary code to gray code conversion

56

G→B

S,D

D P

Gray code to binary code conversion

57

DECOD

S,Ns,N1,D

P

Liner decode

58

ENCOD

S,Ns,N1,D

P

Encode

61

→SEC

S,D

P

Convert the time data (hours, minutes, seconds) of the three successive registers starting from S into seconds data then store to D

62

→HMS

S,D

P

Convert the seconds data of S into time data (hours, minutes, seconds) and store the data in the three successive registers starting from D

63

→HEX

S,N,D

P

Hexadecimal string to data conversion

64

→ASCII

S,N,D

P

Data to hexadecimal string conversion

Code Conversion Instruction List

  • Flow Control Instructions

★ 0

MC

N

The start of master control loop

★ 1

MCE

N

The end of master control loop

★ 2

SKP

N

The start of skip loop

★ 3

SKPE

N

The end of skip loop

END

End of Program

22

BREAK

P

Exit from FOR-NEXT loop

65

LBL

1~6 alphanumeric

Define the label with 1~6 alphanumeric characters

66

JMP

LBL

P

Jump to LBL label and continues the program execution

67

CALL

LBL

P

Call the sub-program begin with LBL label

68

RTS

Return to the calling main program from sub-program

69

RTI

Return to interrupted main program from sub-program

70

FOR

N

Define the starting point of the FOR Loop and the loop count N

71

NEXT

Define the end of FOR loop

165

FLBL

LBL

Define the label with 1~6 alphanumeric characters in FCM.

166

FJMP

LBL

P

Jump to LBL label and continues the program execution in FCM

199

TXTDF

LN

Ladder Program blocking function

Flow Control Instructions List

  • PID Control

30

PID

Ts,SR,OR,PR,WR

D

General PID operation (Main Unit)

38

PID2

ID,CH,SR,OR,PR,WR

General PID operation (Expansion Module)

99

TPCTL2

ID,CH,SR,PR,OR,WR

PID for temperature control (Expansion Module)

PID Control List

  • I/O Instructions

74

IMDIO

D,N

P

Update the I/O signal on the main unit immediately

83

SPD

S,TI,D

Speed detection

I/O Instructions List

  • Cumulative Timer Instructions

87

T.01S

CV,PV

Cumulative timer using 1mS as the time base

88

T.1S

CV,PV

Cumulative timer using 10mS as the time base

89

T1S

CV,PV

Cumulative timer using 100mS as the time base

Cumulative Timer Instructions List

  • Watch Dog Timer Instructions

90

WDT

N

P

Set the WDT timer time out time to N mS

91

RSWDT

P

Reset the WDT timer to 0

Watch Dog Timer Instructions List

  • High Speed Counter / Timer Instructions

92

HSCTR

CN

DP

Read the current CV value of the hardware HSCs, HSC0~HSC3, or HST on SOC to the corresponding CV register in the PLC respectively

93

HSCTW

S,CN,D

DP

Write the CV or PV register of HSC0~HSC3 or HST in the PLC to CV or PV register of the hardware HSC or HST on SOC respectively

High Speed Counter / Timer Instructions List

  • Ramp / Soak Instructions

98

RAMP2

Om,Ta Td,Rt Rc,WR

Tracking type ramp function for analog output

Ramp / Soak Instructions List

  • Communication Function Instructions

150

M-Bus

Pt,SR,WR

P

Modbus protocol communication instruction

151

CLINK

Pt,MD,SR,WR

P

FATEK/Generic protocol communication instruction

152

NCR

Active network communication

156

CMCTL

ID,Pt,Ts,MD,WR

Communication module instruction

Communication Function Instructions List

  • Table Manipulation Instructions

100

R→T

Rs,Td,L,Pr

D P

Register to table data move

101

T→R

Ts,L,Pr,Rd

D P

Table to register data move

102

T→T

Ts,Td,L,Pr

D P

Table to table data move

103

BT_M

Ts,Td,L

D P

Copy the entire contents of Ts to Td

105

R-T_S

Rs,Ts,L,Pr

D P

Table data seek

106

T-T_C

Ta,Tb,L,Pr

D P

Table compare

107

T_FIL

Rs,Td,L

D P

Fill the table Td with Rs

108

T_SHF

IW,Ts,Td,L,OW

D P

Table shift

109

T_ROT

Ts,Fd,L

D P

Table rotate

110

QUEUE

IW,Qu,L,Pr,OW

D P

Data queue(FIFO)

111

STACK

IW,ST,L,Pr,OW

D P

Data stack(FILO)

112

BKCMP

Rs,Ts,L,D

D P

Block compare(CAM switch)

113

SORT

S,D,L

D P

Sorting the registers starting from S length L and store the sorted result to D

114

Z-WR

N

P

Zone set or clear

Table Manipulation Instructions List

  • Matrix Manipulation Instructions

120

MAND

Ma,Mb,Md,L

P

Matrix AND

121

MOR

Ma,Mb,Md,L

P

Matrix OR

122

MXOR

Ma,Mb,Md,L

P

Matrix exclusive OR

123

MXNR

Ma,Mb,Md,L

P

Matrix enclusive OR

124

MINV

Ms,Md,L

P

Matrix invert

126

MBRD

Ms,L,Pr

P

Matrix bit read

128

MBSHF

Ms,Md,L

P

Matrix bit shift

129

MBROT

Ms,Md,L

P

Matrix bit rotate

130

MBCNT

Ms,L,D

P

Calculate the total number of bits that are 0 or 1 in Ms, then store the results into D

Matrix Manipulation Instructions List

  • NC Positioning Instruction

137

ICA

Ps,Is,Po,Ag

Interrupt Constant Angle

138

ICF

Ps,Is,Po,Pd

Interrupt Constant Feed

139

HSPWM

Pw,Op,Rs,Pn,OR,WR

High Speed PWM

140

HSPSO

Ps,SR,WR

HSPSO instruction of NC positioning control

141

MPARA

Ps,SR

Parameter setting instruction of NC positioning control

142

PSOFF

Ps

P

NC pulse output

143

PSCNV

Ps,D

P

Position of pulse unit to engineering unit convert

144

HSPWM2

Pw,Op,Hz,OR

High Speed PWM (Mode2)

147

MHSPO

Gp,SR,WR

Multi-Axis high speed pulse output

148

MPG

Sc,Ps,Po,Mr,WR

Manual Pulse

NC Positioning Instruction List

  • Interrupt Control Instruction

145

EN

LBL

P

Enable HSC, HST, external INT or peripheral operation

146

DIS

LBL

P

Disable HSC, HST, external INT or peripheral operation

Interrupt Control Instruction List

  • Floating Point Number Instruction

200

I→F

S,D

D P

Conversion of integer to floating point munber

201

F→I

S,D

D P

Conversion of floating point munberto integer

202

FADD

Sa,Sb,D

P

Floating point number addition

203

FSUB

Sa,Sb,D

P

Floating point number subtraction

204

FMUL

Sa,Sb,D

P

Floating point number multiplication

205

FDIV

Sa,Sb,D

P

Floating point number divsion

206

FCMP

Sa,Sb

P

Floating point number compare

207

FZCP

S,Su,Sl

P

Floating point number zone compare

208

FSQR

S,D

P

Floating point number square root

209

FSIN

S,D

P

Sin trigonometric instruction

210

FCOS

S,D

P

Cos trigonometric instruction

211

FTAN

S,D

P

Tan trigonometric instruction

212

FNEG

D

P

Change sign of the floating point number

213

FABS

D

P

Floating point number absolute value

218

FASIN

S,D,MD

P

Floating Point arc sine

219

FACOS

S,D,MD

P

Floating Point arc cosine

Floating Point Number Instruction

  • Module Function Instruction

258

MODCONF

OP,ID,CH,SB

Module configuration setting

Module Function Instruction List

  • Motion Basic Instruction

177

MFSysStop

Control motion system stop

185

MFSysRstAlm

Reset motion alarm status

187

MFSysInit

Servo initialization

188

MFSysRCPR

Md,D,Gp

Read motion recipe

189

MFSysRCPW

Md,D,Gp

Write motion recipe

191

MFSysCAMR

Md,D,ID,L

Motion CAM read

192

MFSysCAMW

Md,D,ID,L

Motion CAM write

196

MFSysCAMGen

ID,Md,D,L

Motion CAM Generation

235

MFSysSetVirt

AX

Set real axis to virtual axis

236

MFSDOR

S,I,SI,LN,EC,D

Read EtherCAT slave parameters

237

MFSDOW

S,I,SI,LN,EC,D

Write EtherCAT slave parameters

Motion Basic Instruction list

  • Motion Mode 1 Instruction

176

MFFlowStart

ID

Start the motion flow

181

MFChgTbPrm

Gp,ID,N,D

Change motion parameters

182

MFFlowPause

ID

Pause the motion flow

183

MFFlowResume

ID

Resume the motion flow

184

MFFlowHalt

ID

Halt the motion flow

186

MFFlowStop

ID

Stop the motion flow

198

MFMapTbPrm

Gp,N,L

Set Motion Parameter Mapping Data

Motion Mode 1 list

  • Motion Mode 2 Instruction

178

MFHome

AX

Control the axis homing

179

MFPointMov

PT

Start point position control

180

MFJog

AX,D,MD

Control the axis homing

181

MFChgTbPrm

Gp,ID,N,D

Change motion parameters

198

MFMapTbPrm

Gp,N,L

Set Motion Parameter Mapping Data

Motion Mode 2 Instruction list

  • Motion Mode 3 Instruction

178

MFHome

AX

Control the axis homing

180

MFJog

AX,D,MD

Control the axis homing

193

MFGearMPG

M,S,N,D,T

D

Motion axis gear in

194

MFVelCtl

AX,V,MX

D

Motion Velocity Control

195

MFTorqCtl

AX,T,MXf

D

Motion Torque Control

197

MFAxMov

AX,MD,Ps,V,A,D,SA,SD,DR,BP

D

Motion Axis Movement

238

MFAxLMov

TAX,MD,DR,BF,D,EC

Move axes along a linear path

239

MFAxCirMov

TAX,MD,DR,BF,D,EC

Move axes along a circular path

240

MFPathMov

AX1,AX2,AX3,PT,V,TA,TD,SA,SD,EC

Motion Mode 3 Instruction list