7-1 Power Module Specifications
7-1-1 MPA024-24 Specification
Appearance and Function

MPA024-24部位名稱
Technical Specifications
MPA024-24 Technical Specifications Table
|
Item |
Technical Specifications |
|
|
Model |
MPA024-24 |
|
|
Input |
Input voltage |
100~240VAC |
|
Input frequency |
50/60Hz |
|
|
Maximum input current |
1A max. |
|
|
Inrush current(cold start) |
22A/115Vac (44A/230Vac) |
|
|
Withstand voltage |
3,000 VAC (Primary-secondary), 1,500 VAC (Primary-PE), 500 VAC (Secondary-PE) |
|
|
Insulation resistance |
>100MΩ/500VDC |
|
|
Fuse |
2A |
|
|
Hold-up time |
>15ms/ 115VAC,>60ms/ 220VAC |
|
|
Isolation Type |
Transformer/ Photocoupler Isolation,1500VAC/1 minute |
|
|
Power indication |
LED (green) |
|
|
output |
Rated output power |
24W (Shared CPU dedicated power supply and external Sensor power supply) |
|
Rated output current |
1A (Shared CPU dedicated power supply and external Sensor power supply) |
|
|
Output voltage range |
24VDC±1% |
|
|
Conversion efficiency |
86%/110VAC,87%/220VAC |
|
|
Protection |
Overvoltage protection |
Latching overvoltage protection, re-power on to recover 34V~36V |
|
Overcurrent protection |
Method: Foldback overload protection, automatically recover when overload is removed 101%~133% rated output power |
|
|
Operating Ambient Temperature |
0~55℃ |
|
|
Relative Humidity |
20 ~ 90% (non-condensing) |
|
|
Altitude |
≦2000m |
|
|
Vibration (Fixed by DIN RAIL) |
5~8.4Hz Amplitude: 3.5mm 8.4~150Hz Constant acceleration:19.6m/s^2(2G) 10G, 10 times each along the 3 axes (IEC61131-2 Standard) |
|
|
Shock |
10G, 3 times each along the 3 axes |
|
|
Noise Suppression |
1500Vp-p,Width 1us |
|
|
Withstand Voltage |
1500 VAC 1 minute (Between power terminals and input/output terminals, and between all external terminals and the housing) |
|
|
Certification |
CE |
|
Status Indicator
MPA024-24 Status Indicator Table
|
Name |
instruction |
|
PWR LED |
Power ON: green light Power OFF: no light |
7-1-2 MPA048-24 Specification
Appearance and Function

MPA048-24 Appearance
Technical Specifications
MPA048-24 Technical Specifications Table
|
Item |
Technical Specifications |
|
|
Model |
MPA048-24 |
|
|
Input |
Input voltage |
100~240VAC |
|
Input frequency |
50/60Hz |
|
|
Maximum input current |
1A max. |
|
|
Inrush current(cold start) |
22A/115Vac (44A/230Vac) |
|
|
Withstand voltage |
3,000 VAC (Primary-secondary), 1,500 VAC (Primary-PE), 500 VAC (Secondary-PE) |
|
|
Insulation resistance |
>100MΩ/500VDC |
|
|
Fuse |
2A |
|
|
Hold-up time |
>15ms/ 115VAC,>60ms/ 220VAC |
|
|
Isolation Type |
Transformer/ Photocoupler Isolation,1500VAC/1 minute |
|
|
Power indication |
LED (green) |
|
|
output |
Rated output power |
48W (Shared CPU dedicated power supply and external Sensor power supply) |
|
Rated output current |
2A (Shared CPU dedicated power supply and external Sensor power supply) |
|
|
Output voltage range |
24VDC±1% |
|
|
Conversion efficiency |
86%/110VAC,87%/220VAC |
|
|
Protection |
Overvoltage protection |
Latching overvoltage protection, re-power on to recover 34V~36V |
|
Overcurrent protection |
Method: Foldback overload protection, automatically recover when overload is removed 101%~133% rated output power |
|
|
Operating Ambient Temperature |
0~55℃ |
|
|
Relative Humidity |
20 ~ 90% (non-condensing) |
|
|
Altitude |
≦2000m |
|
|
Vibration (Fixed by DIN RAIL) |
5~8.4Hz Amplitude: 3.5mm 8.4~150Hz Constant acceleration:19.6m/s^2(2G) 10G, 10 times each along the 3 axes (IEC61131-2 Standard) |
|
|
Shock |
10G, 3 times each along the 3 axes |
|
|
Noise Suppression |
1500Vp-p,Width 1us |
|
|
Withstand Voltage |
1500 VAC 1 minute (Between power terminals and input/output terminals, and between all external terminals and the housing) |
|
|
Certification |
CE |
|
Status Indicator
MPA048-24 Status Indicator Table
|
Name |
instruction |
|
PWR LED |
Power ON: green light Power OFF: no light |
Tip: press ← → to switch chapters, Ctrl+K to search